Sewage Treatment Plant and Septic Tank Systems - HOME
SEPTIC TANK CONVERSION PLANT
SEWAGE TREATMENT PLANT
SEPTIC TANK SYSTEMS
Sewage Treatment Options
Sewage Treatment Unit - SELECTION
New Sewage Regulations - EPP2
Cesspits and Cesspools
Problems
Septic Tank Problems
SOAKAWAY
Installation, Repairs and Servicing
Grease Traps
Useful Links
Sitemap
Latest News
Contact Us
Funny but True Toilet News
Testimonials
Terms and Conditions

SEPA
Register your septic tank and sewage treatment plant today
Environment Agency
Contact Us
 
The Byre
Foggathorpe
Selby
North Yorkshire
  
Tel 01757 288022
Tel 01757 289423

Modular Aeration Sewage Treatment Plant Systems

MODULINE aeration wastewater treatment systems

Sewage Treatment Plant suitable for difficult ground conditions

Moduline sewage treatment plant system - shallow installation image

The Moduline aeration wastewater treatment system is a high performing 3 stage modular sewage system which is very versatile and has several significant features and benefits over some single vessel installations. It is ideal for ground conditions which require a shallow excavation, eg. high water tables, rock, etc as the 6 person model has an in-ground depth of only 1.075 metres!   All plants are designed to treat effluent to a standard of 20:30:20. Moduline sewage treatment systems have been designed to cater for sewage loading of up to 75 people.

 Checklist

Electricity required YES
Emptying Interval
1 year
Primary tank
YES
Internal moving parts
NO
Performs during intermittent use (holiday lets, etc.) YES
Concrete backfill
YES
Visually intrusive (large lids, kiosk, etc.)
NO
Expensive servicing
NO
Tank warranty period
25 years
Easy Installation
YES

Tech Specs

6 Person (shallow) 6 (Normal) 12 Person 20 Person 35 Person 50 Person 75 Person
Design Flow Rate 1200 litres 1200 litres 2400 litres 4000 litres 7000 litres 10000 litres 15000 litres
BOD (Kg) 0.36 0.36 0.72 1.2 2.1 3 4.5
Height (mm) 1075 1610 1610 2100 1920 2350 2550
Width 1260 1260 1260 1260 1560 2150 2150
Length (mm) 4200 4200 4200 4200 5200 7350 9300
Inlet invert (mm) 350 500 500 500 500 500 500

Features 6 person shallow depth sewage plant end view

  • High Performance Polyethylene Chambers   
  • Micron filter screening
  • Bio-Ball media
  • Activated sludge return
  • Pumped & Gravity discharge options
  • Large media zone
  • Low profile installation option

Benefits

  • In-Ground depth of only 1075mm for the 6 person shallow plant
  • EN 12566-3 2005 Certification 
  • Durable & Robust
  • High quality discharge as standard
  • High performance aerobic treatment
  • Low maintenance costs
  • Easy access to all chambers
  • Ease of installation
  • Longer intervals between de-sludging
  • Suitable for all ground situations
  • Can be fitted with effluent filters for tertiary treatment

How the Moduline Sewage Treatment Plant Works

Moduline sewage treatment system shallow cs

Stage 1

Waste water enters the systems' primary settlement chamber. Heavy solids drop to the base where they are separated from the liquid. Anaerobic breakdown now begins to occur and improves the water quality by up to 30%, producing a secondary effluent. Any suspended solids (sanitary towels, tissue etc) are filtered out by the micron filter on the outlet from this chamber.

Stage 2

The filtered effluent then enters the second stage of the sewage treatment process which is the aeration of the effluent. In chamber 2 masses of naturally occurring bacteria inhabit specially designed filter media beds. The bacteria are sustained and proliferated with air, which is continuously supplied by a above ground compressor to a high quality diffuser in the base of the chamber. As the effluent flow’s through the filter media the bacteria feed on the impurities, consuming and removing them. Small quantities of bacteria known as “sludge” are produced as a biproduct. This sludge gathers at the bottom of the module where it is continuously fed back to chamber one.  This process enhances the performance.

Stage 3

The treated effluent / liquid now passes through a second micron filter for final polishing of the liquid from the aeration chamber. It enters the third and final settlement module which can be fitted with a final effluent filter for tertiary treatment, if required.  The remaining treated liquid now meets the required discharge quality standard to be safely passed out of the plants into the watercourse or soakaway.

Technologybio balls 

All the Moduluine sewage treatment systems feature our new BIO BALL filter media, which has been designed to increase the efficiency of the biological process. BIO BALL media provide’s excellent ventilation to speed-up the aerobic reaction and also have exceptional void area to prevent blocking and the resulting slowing-down of the process that might occur. The BIO BALL feature specially designed profiled fins which increase the total surface area and encourage the formation of the biological films of bacteria, protozoa and fungi which will eat and biologically break down the organic content. The edges of the fins are serrated, this enables them to interlock in the filter bed giving excellent mechanical strength. The BIO BALL technology means that media maintains improved performance in the MODULINE sewage treatment system.
Moduline 50 sewage plant image
Moduline 50 person sewage treatment plant

See PRODUCTS for other sewage treatment plants



Powered by Create

Latest News

Keep up to date with the latest news on waste water issues.

BIOROCK replaces mandatory cesspools in the Channel Islands.

Under the new EPP2 regulations, only plants with the EN 12566-3 2005 Certification are allowed to register for the Discharge Permit or Exemption now required by the Environment Agency.

Which plants in the UK have the EN 12566-3 Certificate? - See the list.

BIOROCK achieves amazing 4:3:3 for its new EN test results!

Installers Wanted
Installers wanted throughout UK and Ireland for all types of treatment plant installations.
Tel 01757 288022
Act on CO2
biorock sewerage treatment unit image
No Electricity
BIOROCK
 The system you have been waiting for!
Septic Tank Failure
Free surveys for soakaway failures.  Full reports  for Litigation
Caravan Parks
Valence  large wastewater systems are excellent value for money.
Wastewater Tutorial
Sewage treatment plant and septic tank system design and construction: